States. Our products and operations are subject to extensive
and rigorous regulation by the FDA. The FDA regulates the research, testing,
manufacturing, safety, labeling, storage, recordkeeping, promotion,
distribution and production of medical devices in the United States to provide
reasonable assurance that medical products distributed domestically are safe
and effective for their intended uses. The Federal Trade Commission also
regulates the advertising of our products.
Under the Federal Food, Drug, and Cosmetic Act, medical devices are classified into one of three classes Class I, Class II or Class III depending on the degree of risk associated with each medical device and the extent of control needed to provide reasonable assurances with respect to safety and effectiveness. Our current products are Class I, II and III medical devices, with most being classified as Class II devices and our IOLs being classified as Class III devices in the United States, subject to certain exceptions. Class I devices are those for which safety and effectiveness can be reasonably assured by adherence to a set of guidelines, which include compliance with the applicable portions of the FDAs Quality System Regulation, facility registration and product listing, reporting of adverse medical events, and appropriate, truthful and non-misleading labeling, advertising, and promotional materials, referred to as the general controls. Some Class I, also called Class I reserved, devices also require premarket clearance by the FDA through the 510(k) premarket notification process described below. Many Class I products are exempt from the premarket notification requirements. 8 Class II devices are those which are subject to the general controls and may require adherence to certain performance standards or other special controls (as specified by the FDA) and clearance by the FDA: Premarket review and clearance by the FDA for these devices is accomplished through the 510(k) premarket notification procedure. For most Class II devices, the manufacturer must submit to the FDA a premarket notification, demonstrating that the device is substantially equivalent to a legally marketed device. If the FDA agrees that the device is substantially equivalent, it will grant clearance to commercially market the device. By regulation, the FDA is required to complete its review of a 510(k) within 90 days of submission of the notification. As a practical matter, clearance often takes longer. The FDA may require further information, including clinical data, to make a determination regarding substantial equivalence. If the FDA determines that the device, or its intended use, is not substantially equivalent, the FDA will place the device, or the particular use of the device, into Class III, and the device sponsor must then fulfill much more rigorous premarketing requirements, known as premarket approval. A Class III product is a product that has a new intended use or uses advanced technology that is not substantially equivalent to a use or technology with respect to a legally marketed device, or for which there is not sufficient information to establish performance standards or special controls to provide reasonable assurance of the devices safety and effectiveness and the product is represented to be for use in supporting or sustaining human life or for a use that is of substantial importance in preventing impairment of human health or presents a potential unreasonable risk of illness or injury. The safety and effectiveness of Class III devices cannot be reasonably assured solely by the general controls and the other requirements described above. Therefore, these devices almost always require formal clinical studies to demonstrate safety and effectiveness. FDA approval of a premarket approval application is required before marketing a Class III product. The premarket approval application process is much more demanding than the 510(k) premarket notification process. A premarket approval application, which is intended to provide reasonable assurance that the device is safe and effective, must be supported by extensive data, including data from preclinical studies and human clinical trials and existing research material, and must contain a full description of the device and its components, a full description of the methods, facilities and controls used for manufacturing, and proposed labeling. Following receipt of a premarket approval application, once the FDA determines that the application is sufficiently complete to permit a substantive review, the FDA will accept the application for review. The FDA, by statute and by regulation, has 180 days to review a filed premarket approval application, although the review of an application more often occurs over a significantly longer period of time. A maximum time of 360 days is allowed to respond to deficiencies. In approving a premarket approval application or clearing a 510(k) notification, the FDA may also require some form of postmarket surveillance, whereby the manufacturer follows certain patient groups for a number of years and makes periodic reports to the FDA on the clinical status of those patients when necessary to protect the public health or to provide additional safety and effectiveness data for the device. When FDA approval of a device requires human clinical trials, and if the clinical trial presents a significant risk (as defined by the FDA) to human health, the device sponsor is required to file an investigational device exemption, or IDE, application with the FDA and obtain investigational device exemption approval prior to commencing the human clinical trial. If the clinical trial is considered a nonsignificant risk, investigational device exemption submission to the FDA is not required. Instead, only approval from the Institutional Review Board overseeing the clinical trial is required, although the study is still subject to FDA oversight under other provisions of the IDE regulation. Human clinical studies are generally required in connection with approval of Class III devices and to a much lesser extent for Class I and II devices. Clinical trials conducted abroad for FDA approval must comply with both local regulations and FDA guidance. This excerpt taken from the EYE 10-K filed Mar 14, 2006. United
States. Our products and operations are subject to extensive
and rigorous regulation by the FDA. The FDA regulates the research, testing,
manufacturing, safety, labeling, storage, recordkeeping, promotion,
distribution and production of medical devices in the United States to provide
reasonable assurance that medical products distributed domestically are safe
and effective for their intended uses. The Federal Trade Commission also
regulates the advertising of our products.
Under the Federal Food, Drug, and Cosmetic Act, medical devices are classified into one of three classes Class I, Class II or Class III depending on the degree of risk associated with each medical device and the extent of control needed to provide reasonable assurances with respect to safety and effectiveness. Our current products are Class I, II and III medical devices, with most being classified as Class II devices and our IOLs being classified as Class III devices in the United States, subject to certain exceptions.
Class I devices are those for which safety and effectiveness can be reasonably assured by adherence to a set of guidelines, which include compliance with the applicable portions of the FDAs Quality System Regulation, facility registration and product listing, reporting of adverse medical events, and appropriate, truthful and non-misleading labeling, advertising, and promotional materials, referred to as the general controls. Some Class I, also called Class I reserved, devices also require premarket clearance by the FDA through the 510(k) premarket notification process described below. Many Class I products are exempt from the premarket notification requirements.
Class II devices are those which are subject to the general controls and may require adherence to certain performance standards or other special controls (as specified by the FDA) and clearance by the FDA: Premarket review and clearance by the FDA for these devices is accomplished through the 510(k) premarket notification procedure. For most Class II devices, the manufacturer must submit to the FDA a premarket notification, demonstrating that the device is substantially equivalent to a legally marketed device.
If the FDA agrees that the device is substantially equivalent, it will grant clearance to commercially market the device. By regulation, the FDA is required to complete its review of a 510(k) within 90 days of submission of the notification. As a practical matter, clearance often takes longer. The FDA may require further information, including clinical data, to make a determination regarding substantial equivalence. If the FDA determines that the device, or its intended use, is not substantially equivalent, the FDA will place the device, or the particular use of the device, into Class III, and the device sponsor must then fulfill much more rigorous premarketing requirements, known as premarket approval.
A Class III product is a product which has a new intended use or uses advanced technology that is not substantially equivalent to a use or technology with respect to a legally marketed device, or for which there is not sufficient information to establish performance standards or special controls to provide reasonable assurance of the devices safety and effectiveness and the product is represented to be for use in supporting or sustaining human life or for a use that is of substantial importance in preventing impairment of human health or presents a potential unreasonable risk of illness or injury. The safety and effectiveness of Class III devices cannot be reasonably assured solely by the general controls and the other requirements described above. Therefore, these devices almost always require formal clinical studies to demonstrate safety and effectiveness.
FDA approval of a premarket approval application is required before marketing a Class III product. The premarket approval application process is much more demanding than the 510(k) premarket notification process. A premarket approval application, which is intended to provide reasonable assurance that the device is safe and effective, must be supported by extensive data, including data from preclinical studies and human clinical trials and existing research material, and must contain a full description
9
of the device and its components, a full description of the methods, facilities and controls used for manufacturing, and proposed labeling. Following receipt of a premarket approval application, once the FDA determines that the application is sufficiently complete to permit a substantive review, the FDA will accept the application for review. The FDA, by statute and by regulation, has 180 days to review a filed premarket approval application, although the review of an application more often occurs over a significantly longer period of time, up to several years.
In approving a premarket approval application or clearing a 510(k) notification, the FDA may also require some form of postmarket surveillance, whereby the manufacturer follows certain patient groups for a number of years and makes periodic reports to the FDA on the clinical status of those patients when necessary to protect the public health or to provide additional safety and effectiveness data for the device.
When FDA approval of a device requires human clinical trials, and if the clinical trial presents a significant risk (as defined by the FDA) to human health, the device sponsor is required to file an investigational device exemption, or IDE, application with the FDA and obtain investigational device exemption approval prior to commencing the human clinical trial. If the clinical trial is considered a nonsignificant risk, investigational device exemption submission to the FDA is not required. Instead, only approval from the Institutional Review Board overseeing the clinical trial is required, although the study is still subject to FDA oversight under other provisions of the IDE regulation. Human clinical studies are generally required in connection with approval of Class III devices and to a much lesser extent for Class I and II devices. Clinical trials conducted abroad must also comply with local regulations.