This excerpt taken from the C 10-K filed Feb 22, 2008. Car 21: 12.4 seconds. Pressure: Design and factory test fluid system components for 500 p.s.i. Do not exceed operating pressure of 400 p.s.i. All elevator equipment provided under this contract, including power unit, controller, oil supply lines and their support shall be mechanically isolated from the building structure and electrically isolated from the building power supply and each other to minimize the possibility of objectionable noise and vibrations being transmitted to occupied areas of the building. Measure noise level of the elevator equipment and its operation shall not exceed 50 dBA in elevator lobby and 60 dBA in elevator car under any condition including door operation and with the car ventilation exhaust blower on its highest speed.