RVBD » Topics » Building Standard Materials

This excerpt taken from the RVBD 10-K filed Feb 15, 2008.

Building Standard Materials

 

Ceiling Tile:   USG Interiors
  Mars ClimaPlus 2"2"3/4'
.   High LR .92
  Fineline Beveled
  Edge (FLB) Ceiling Tile (USGI 86985)
  or
 

Armstrong Optima with foil backing,

product number 3335,

with an acoustic rating of .

.90 NRC and 20+ CAC

Ceiling Suspension System:   USG Interiors
 

Donn Fineline 1/8" (DXFF) Grid System

Main Runners and Cross Tees for a 2"2' system

(DXFF2924, DXFF229 and DXFF429N)

Doors:   All doors to be 9'-0' height. Main Tenant doors will be fire rated, solid core wood with Figured Annigre finish in rated hollow metal frames, painted. Secondary, non-rated doors to be solid core wood with Figured Annigre finish with aluminium frame.
Door Hardware:   Schlage, fully mortised, lever: L-series 03, finish: 625 bright chromium plated
Window Blinds:   Levelor, Riviera Dust Guard 1" Blind with SheerView slats and tiltone colors
Neutral side: 115 Dover   alternate neutral side: 112 Alabaster
Window side: 862 Pearl Grey   alternate window side: NA

**     Required option: Restrictive Cam Tilter for uniform window side (exterior) 862 Pearl Grey color

Tenant Light Fixtures:   Columbia P4 Parabolic or Lightolier, 3 Lamps with T-8 lamps. Lighting connected to the building’s Energy Management system.
VAV Boxes:   Titus or Price, Direct Digital Control system connected to the building’s Energy Management System
Thermostats:   White, surface mounted thermostat with set point adjustment and room Temperature display.
Duct Work:   Externally insulated sheet metal duct build to sheet metal duct industry standard for leakage and performance. Maximum of 6 feet of flexible duct work will be utilized for connection from VAV box to diffuser. All sheet metal duct will be suitable for re-use by future tenants.

 

  

EXHIBIT I

-1-

  


Sprinklers:    Semi Recess Type with white metal escutcheon. Central Model 1 or Equal.
Air Diffusers:    Light Troffer Diffusers titus LTTI or Price
Light Switches:    White, Non-sensor type Leviton rocker type or Motion Sensor type: Novitas, Watt Stopper or equal.
Outlet:    white, Leviton Commercial receptacles.
Speakers and Strobe Lights:    Speakers: Gentex or equal 4" or 8" SPK series. Speakers to be Connected to building fire alarm system.
   Strobes: Wheelock Candella or equal wall mounted, UL listed Strobes to be connected to building fire alarm system.
Pull Stations:    Cerberus Pyrotronics, Simplex or equal. UL listed, manual single Action pull station. Surface or Semi-flush installation. Stations to be connected to building fire alarm system.
Exit Lights:    UL Listed, Low energy LED type. Emergi-Lite Preceptor Series or equal.

 

  

EXHIBIT I

-2-

  


Wikinvest © 2006, 2007, 2008, 2009, 2010, 2011, 2012. Use of this site is subject to express Terms of Service, Privacy Policy, and Disclaimer. By continuing past this page, you agree to abide by these terms. Any information provided by Wikinvest, including but not limited to company data, competitors, business analysis, market share, sales revenues and other operating metrics, earnings call analysis, conference call transcripts, industry information, or price targets should not be construed as research, trading tips or recommendations, or investment advice and is provided with no warrants as to its accuracy. Stock market data, including US and International equity symbols, stock quotes, share prices, earnings ratios, and other fundamental data is provided by data partners. Stock market quotes delayed at least 15 minutes for NASDAQ, 20 mins for NYSE and AMEX. Market data by Xignite. See data providers for more details. Company names, products, services and branding cited herein may be trademarks or registered trademarks of their respective owners. The use of trademarks or service marks of another is not a representation that the other is affiliated with, sponsors, is sponsored by, endorses, or is endorsed by Wikinvest.
Powered by MediaWiki