Building Standard Materials
Ceiling Tile:
USG Interiors
Mars ClimaPlus 2"2"3/4'
.
High LR .92
Fineline Beveled
Edge (FLB) Ceiling Tile (USGI 86985)
or
Armstrong Optima with foil backing,
product number 3335,
with an acoustic rating of .
.90 NRC and 20+
CAC
Ceiling Suspension System:
USG Interiors
Donn Fineline 1/8" (DXFF) Grid System
Main Runners
and Cross Tees for a 2"2' system
(DXFF2924, DXFF229 and DXFF429N)
Doors:
All doors to be 9'-0' height. Main Tenant doors will be fire rated, solid core wood with Figured Annigre finish in rated hollow metal frames, painted. Secondary, non-rated doors to be
solid core wood with Figured Annigre finish with aluminium frame.
Levelor, Riviera Dust Guard 1" Blind with SheerView slats and tiltone colors
Neutral side: 115 Dover
alternate neutral side: 112 Alabaster
Window side: 862 Pearl Grey
alternate window side: NA
** Required option: Restrictive Cam Tilter for uniform window side (exterior) 862 Pearl Grey color
Tenant Light Fixtures:
Columbia P4 Parabolic or Lightolier, 3 Lamps with T-8 lamps. Lighting connected to the buildings Energy Management system.
VAV Boxes:
Titus or Price, Direct Digital Control system connected to the buildings Energy Management System
Thermostats:
White, surface mounted thermostat with set point adjustment and room Temperature display.
Duct Work:
Externally insulated sheet metal duct build to sheet metal duct industry standard for leakage and performance. Maximum of 6 feet of flexible duct work will be utilized for connection from VAV
box to diffuser. All sheet metal duct will be suitable for re-use by future tenants.
EXHIBIT I
-1-
Sprinklers:
Semi Recess Type with white metal escutcheon. Central Model 1 or Equal.
Air Diffusers:
Light Troffer Diffusers titus LTTI or Price
Light Switches:
White, Non-sensor type Leviton rocker type or Motion Sensor type: Novitas, Watt Stopper or equal.
Outlet:
white, Leviton Commercial receptacles.
Speakers and Strobe Lights:
Speakers: Gentex or equal 4" or 8" SPK series. Speakers to be Connected to building fire alarm system.
Strobes: Wheelock Candella or equal wall mounted, UL listed Strobes to be connected to building fire alarm system.
Pull Stations:
Cerberus Pyrotronics, Simplex or equal. UL listed, manual single Action pull station. Surface or Semi-flush installation. Stations to be connected to building fire alarm system.
Exit Lights:
UL Listed, Low energy LED type. Emergi-Lite Preceptor Series or equal.
EXHIBIT I